Comparative study on chiller configurations in an efficient chilled water system in a tropical high-rise building

Show simple item record

dc.contributor.advisor Wijewardena, MA
dc.contributor.author Iddagoda, PK
dc.date.accessioned 2025-01-16T08:10:15Z
dc.date.available 2025-01-16T08:10:15Z
dc.date.issued 2023
dc.identifier.citation Iddagoda, P.K. (2023). Comparative study on chiller configurations in an efficient chilled water system in a tropical high-rise building [Master's theses, University of Moratuwa]. Institutional Repository University of Moratuwa. http://dl.lib.uom.lk/handle/123/23147
dc.identifier.uri http://dl.lib.uom.lk/handle/123/23147
dc.description.abstract Energy-efficiency concerns have changed several design trends, and chilled water systems are now designed for different delta T values. The delta T affects the coil sizes of Air Handling Unit (AHU) and Fan Coil Unit (FCU), pumping power and pipe sizes of the chilled water distribution system and capacity of the chiller. Designing a chilled-water system for a higher delt T (ΔT), reduce the initial costs due to smaller valves, piping, pumps and also reduce the operating cost due to low chilled water flow rates. However, this topic is accompanied by a multitude of arguments and contradictions. This research was based on the comparative study of parallel flow and series counter flow (SCF) chiller arrangement for different ΔT values and finding the best chiller configuration and ΔT value with higher Coefficient of Performance (COP). For this comparative study, a high-rise commercial building was selected, and the chilled water system was designed by conducting cooling load calculations and appropriately selecting chillers and pumps. For two chillers with the same capacity configured in parallel and SCF arrangement, chilled water flow rate, chiller lift, and COP values were calculated for various ΔT values. Additionally, a comparative study was also done for the chilled water pump power and distribution system piping sizes for different flow rates. The CoolPack software was used for the calculation of COP values. Based on the study, it was observed that there was a decrease in chilled water flow rate as the ΔT increases. The analysis also revealed that compared to parallel flow chillers, SCF chillers have chiller lift reduction and higher COP for both conventional and high ΔT system. It also found that chiller lift does not depend on ΔT value and it only depends on chilled water supply temperature. The maximum COP was attained at a chilled water supply temperature of 9.0 0C which was the maximum supply temperature selected with 100C ΔT (beyond the 8.30C ΔT recommended by ASHRAE), resulting in a COP value of 6.60. There was an improvement in the COP value of 1.36 for 10 0C ΔT with a temperature range of 9-19 0C using the SCF arrangement compared to the conventional 50C ΔT with temperature range of 7-12 0C with parallel configuration. iii A reduction of about 50% in flow rate and pump power were observed for a 100C ΔT compared to conventional 50C ΔT. In this building, the percentage reduction in pipe sizes within the chilled water distribution system remains constant at 29.29 of % for a 100C ΔT compared to a 50C ΔT. The research concludes that utilizing design strategies such as higher temperature differences, elevated supply chilled water temperatures, and SCF chiller configurations can enhance the chiller efficiency, reduce pumping energy use, and piping installation costs, leading to overall cost savings for chiller system. Keywords: Conventional ΔT, High ΔT, Series Counter Flow Chillers, Parallel Chillers, COP, Chiller lift en_US
dc.language.iso en en_US
dc.subject PARALLEL CHILLERS
dc.subject COP
dc.subject CHILLER LIFT
dc.subject CONVENTIONAL ΔT
dc.subject HIGH ΔT
dc.subject SERIES COUNTER FLOW CHILLERS
dc.subject MECHANICAL ENGINEERING – Dissertation
dc.subject BUILDING SERVICES ENGINEERING– Dissertation
dc.subject MSc in Building Services Engineering
dc.title Comparative study on chiller configurations in an efficient chilled water system in a tropical high-rise building en_US
dc.type Thesis-Abstract en_US
dc.identifier.faculty Engineering en_US
dc.identifier.degree MSc in Building Services Engineering en_US
dc.identifier.department Department of Mechanical Engineering en_US
dc.date.accept 2023
dc.identifier.accno TH5493 en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record