Show simple item record

dc.contributor.author De Seram, HSNP
dc.contributor.author Rathnayake, RMM
dc.contributor.author Weragoda, VSC
dc.contributor.editor Sivahar, V
dc.contributor.editor Sitinamaluwa, HS
dc.date.accessioned 2022-03-16T03:43:54Z
dc.date.available 2022-03-16T03:43:54Z
dc.date.issued 2019-01
dc.identifier.citation De Seram, H.S.N.P., Rathnayake, R.M.M., & Weragoda, V.S.C. (2019). Investigation of cause of uncured resin in carbon fiber razor cables [Abstract]. In V. Sivahar & H.S. Sitinamaluwa (Eds.), Dreams to reality through innovative materials (p. 20). Department of Materials Science and Engineering, University of Moratuwa. en_US
dc.identifier.uri http://dl.lib.uom.lk/handle/123/17382
dc.description.abstract This research project investigates a mechanical failure of razor cables manufactured by a leading carbon fiber boom, rigging and spars manufacturing company in Sri Lanka. This project was aimed at detecting the cause of failure of razor cables when subjected to coiling for transportation. In preliminary studies, it was apparent that the localized variations in the curing process could be a possible cause for the failure. Also, other factors such as the presence of moisture, the behavior of the epoxy resin, curing method could affect the outcome of the curing process. Through this project, authors attempted to establish the most probable cause for the failure and to determine a method to identify the areas susceptible to failure to minimize the production of potentially defective products. It was hypothesized that the uneven curing of the razor cables could be a major reason for failure. To test that, eddy current and di-electrometry techniques were used as the test methods for monitoring of the degree of curing. However, it was observed that eddy current method did not give any useful indications about the degree of curing. The di-electrometric technique showed different dielectric capacitance values for cured and uncured resins. Therefore, using dielectric capacitance theory, a test probe was designed to distinguish the cured product from the non-cured product. A combination of experimental and theoretical study was carried out to verify whether the curing cycle used is sufficient to complete the curing process. The mathematical model shows that, the curing cycle time was sufficient for complete curing of the epoxy resin. Therefore, it is suggested that the cause of failure could be either a material or pre-curing process related. en_US
dc.language.iso en en_US
dc.publisher Department of Materials Science and Engineering en_US
dc.subject Curing en_US
dc.subject Di-electrometry en_US
dc.subject Eddy current en_US
dc.subject Epoxy resin en_US
dc.title Investigation of cause of uncured resin in carbon fiber razor cables en_US
dc.type Conference-Abstract en_US
dc.identifier.faculty Engineering en_US
dc.identifier.department Department of Materials Science and Engineering en_US
dc.identifier.year 2019 en_US
dc.identifier.conference Materials Engineering Symposium on Innovations for Industry 2019 en_US
dc.identifier.place Katubedda en_US
dc.identifier.pgnos p. 20 en_US
dc.identifier.proceeding Dreams to reality through innovative materials en_US
dc.identifier.email [email protected] en_US